Product Details:
|
Application: | Livestock House Building | Type: | Light Steel Frame Structure Buildings |
---|---|---|---|
Working Scope: | Design,Fabrication, Installation | Raw Steel Material: | Q235B, Q355B |
Surface Treatment: | Painting | Shot Blasting Level: | Sa 2.5 |
Service Life: | 50 Years | Wall And Roof: | Glass Wool |
Highlight: | steel structure building,metal warehouse construction,Livestock House Building Steel Frame Structure |
Attribute | Value |
---|---|
Application | Livestock House Building |
Type | Light Steel Frame Structure Buildings |
Working scope | Design, Fabrication, Installation |
Raw steel material | Q235B, Q355B |
Surface treatment | Painting |
Shot blasting level | Sa 2.5 |
Service life | 50 Years |
Wall and Roof | Glass wool |
Our Light Steel Frame Structure Buildings are specifically designed for Livestock House Building applications. We provide comprehensive design and fabrication services for poultry farms and livestock housing solutions.
The main steel frame structure utilizes:
Surface treatment options include paint or hot dip galvanized finishes for steel structure components.
Feature | Specification |
---|---|
Structure Type | Portal frame, single ridge, two slopes, single span |
Length | 60 m |
Width | 10m |
Eave Height | 3m |
Roof Slope | 10% |
Gable Wall Column Spacing | 7.5m |
Roof Material | Steel cladding sheet |
Wall Material | Steel cladding sheet |
Height difference (indoor/outdoor) | 300mm |
We specialize in contracting projects including:
All structural components, panels, bolts, and accessories are packed with standard packaging suitable for ocean transportation and loaded into 40'HQ containers.
Our skilled workers carefully load products at our factory using cranes and forklifts to prevent any damage during transportation.
Please provide the following information for an accurate quote:
Item | Details Required |
---|---|
1 | Location (where will be built?) - country, area |
2 | Size: length*width*height (mm) |
3 | Wind load (max. wind speed) - kn/m², km/h, or m/s |
4 | Snow load (max. snow height) - kn/m² or mm |
5 | Anti-earthquake requirements - level |
6 | Brickwall needed (if yes, specify height: 1.2m or 1.5m) |
7 | Thermal insulation requirements (EPS, fiberglass wool, rockwool, PU sandwich panels or metal steel sheets) |
8 | Door quantity & size (units, width*height in mm) |
9 | Window quantity & size (units, width*height in mm) |
10 | Crane requirements (if needed: units, max lifting weight in tons, max lifting height in m) |
Contact Person: steven
Tel: 0086-18661691560