|
Product Details:
|
| Features: | Prefab Steel Structure, Large Span, Multi-Floor | Raw Steel Material: | Q235B, Q355B, ASTM A36 |
|---|---|---|---|
| Application: | Steel Workshop, Steel Structure Platform, Structural Roofing, Frame Part | Surface Treatment: | Painting Or Hot-DIP Galvanized |
| Service Life: | 50 Years | Wall And Roof: | Steel Cladding Sheet,Sandwich Panel |
| Columns & Beams: | H-Section Steel | Shot Blasting Level: | SA 2.5 |
| Certification: | CE, AISC, SGS, BV, ISO, GB | Installation: | Engineer Guidance On Site |
| Drawing: | CAD, TEKLA, 3D Model, PKPM, BIM | HS Code: | 9406900090 |
| Transport Package: | Standard Export Package Or Customer′s Requirement | Production Capacity: | 30000ton/Year |
| Connection Form: | Bolt Connection | ||
| Highlight: | Multi Story Steel Structure Hotel,Prefabricated Steel Structure Hotel |
||
| Raw Steel Material | Q235B, Q355B, ASTM A36 |
| Application | Steel Workshop, Steel Structure Platform, Structural Roofing, Frame Part |
| Surface Treatment | Painting or Hot-DIP Galvanized |
| Service Life | 50 Years |
| Wall and Roof | Steel cladding sheet, Sandwich Panel |
| Columns & Beams | H-Section Steel |
| Shot Blasting Level | SA 2.5 |
| Certification | CE, AISC, SGS, BV, ISO, GB |
| Installation | Engineer Guidance on Site |
| Drawing | CAD, TEKLA, 3D Model, PKPM, BIM |
| HS Code | 9406900090 |
| Transport Package | Standard Export Package or Customer's Requirement |
| Production Capacity | 30000ton/Year |
| Component | Specification |
|---|---|
| Main Steel Frame (Column/Beam) | Q235, Q355 Welded H Section Steel |
| Secondary Frame (Purlin) | Q235 C and Z purlin |
| Maintenance System (Roof Panel) | Various sandwich panel options available |
| Live Load on Roof | 120kg/Sqm (Color steel panel surrounded) |
| Finishing Options | Wide range of colors and textures available |
| 1 | Location (where will it be built?) | _____country, area |
| 2 | Size: length*width*height | _____mm*_____mm*_____mm |
| 3 | Wind load (max. wind speed) | _____kn/m2, _____km/h, _____m/s |
| 4 | Snow load (max. snow height) | _____kn/m2, _____mm |
| 5 | Anti-earthquake requirement | _____level |
| 6 | Brickwall needed or not | If yes, 1.2m high or 1.5m high |
| 7 | Thermal insulation requirement | Specify material preference if needed |
| 8 | Door quantity & size | _____units, _____(width)mm*_____(height)mm |
| 9 | Window quantity & size | _____units, _____(width)mm*_____(height)mm |
| 10 | Crane needed or not | If yes, specify capacity and height requirements |
Contact Person: steven
Tel: 0086-18661691560